Code | 99116553 | 99116803 | |||
Name | HPS 60KVA/ 90KVA | HPS 100KVA | |||
Power Countinous mode | 100KVA | ||||
Power Inrush mode | 60KVA/90KVA | ||||
Output | 3phase(6) | 3phase(6) | |||
Characteristic | Isolated | Isolated | |||
VOLTAGE | Range | 150V/300V(4) | 150V/300V(4) | ||
Accuracy | <0.5% | <0.5% | |||
Distortion | <0.6% | <0.6% | |||
Stability of the output voltage | <0.1% | <0.1% | |||
Recovery time of the waveform | <10ms | <10ms | |||
Maximum Compensated drop | 5% f.s | 5% f.s | |||
Recovery-time of drop on wires | <200ms. | <200ms. | |||
Output voltage resolution | 0.025% f.s. | 0.025% f.s. | |||
Inrush function (Max current) |
1PH | RMS continuous (2) 150V | 134 A | ||
RMS continuous (2) 300V | 67 A | ||||
Inrush Current (3 seconds)(2) 150V | 196 A | ||||
Inrush Current (3 seconds)(2) 300V | 98 A | ||||
3PH | RMS continuous (2) 150V | 134 A | |||
RMS continuous (2) 300V | 67 A | ||||
Inrush Current (3 seconds)(2) 150V | 196 A | ||||
Inrush Current (3 seconds)(2) 300V | 98 A | ||||
Countinous function (Max current) |
1PH | RMS continuous (2) 150V | 228 A | ||
RMS continuous (2) 300V | 114 A | ||||
3PH | RMS continuous (2) 150V | 228 A | |||
RMS continuous (2) 300V | 114 A | ||||
FREQUENCY | Output frequency range | 50Hz(5) – 80Hz | 50Hz(5) – 80Hz | ||
Range of synchronization | 45Hz – 65Hz | 45Hz – 65Hz | |||
Frequency resolution | 0.02Hz | 0.02Hz | |||
Frequency precision | 100ppm | 100ppm | |||
SUPPLY | Input supply | 400Vac±10% 3PH | 400Vac±10% 3PH | ||
Maximum Input current | 150A | 250A | |||
Input Frequency | 47Hz-63Hz | 47Hz-63Hz | |||
OTHER | Size (H : W : D) | 1670 : 920 : 825 | 1670 : 920 : 825 | ||
Weight | 550 Kg | 800 kg | |||
Protections | OVP,UVP;OTP | OVP,UVP;OTP | |||
Operation Temperature Range | 0-35°C | 0-35°C | |||
RS232 | YES | YES | |||
RS485 | OPTION | OPTION | |||
LAN | OPTION | OPTION | |||
Firmware with SCPI | OPTION | OPTION | |||
Remote program | PS Interface | PS Interface | |||
Driver Labview | PS Driver rev. 1 | PS Driver rev. 1 | |||
Manual | 62000590_it_en 62000590_de_es Quick start guide Startup sequence |
62000590_it_en 62000590_de_es Quick start guide Startup sequence |
|||
Brochure | HPS 60KVA | HPS 100KVA | |||
FILTERS | Three phase | ● | ● | ||
Isolated | ● | ● | |||
Double range | ● | ● | |||
OVP = Over voltage protection
UVP = Under voltage protection OTP = Over temperature protectionf.s. = Full scale (2) With Resistive load (3) Desk and Rack version (5) It is possible on remote interface to set 10Hz but you must decrease the maximum voltage (6) It is possible to use in single phase mode but with 1/3 of nominal power. It is possible asymmetrical output current |
![]() |
![]() |
||||
---|---|---|---|---|---|
Code | 99116823 | 99116953 | |||
Name | HPS 60KVA/180KVA (100KVA) | HPS 120KVA/360KVA (200KVA) | |||
Power Countinous mode | 100KVA | 200KVA | |||
Power Inrush mode | 60KVA/180KVA(6) | 120KVA/360KVA(6) | |||
Output | 3phase(6) | 3phase(6) | |||
Characteristic | Isolated | Isolated | |||
VOLTAGE | Range | 150V/300V(4) | 150V/300V(4) | ||
Accuracy | <0.5% | <0.5% | |||
Distortion | <0.6% | <0.6% | |||
Stability of the output voltage | <0.1% | <0.1% | |||
Recovery time of the waveform | <10ms | <10ms | |||
Maximum Compensated drop | 5% f.s | 5% f.s | |||
Recovery-time of drop on wires | <200ms. | <200ms. | |||
Output voltage resolution | 0.025% f.s. | 0.025% f.s. | |||
Inrush function (Max current) |
1PH | RMS continuous (2) 150V | 137 A | 279 A | |
RMS continuous (2) 300V | 68 A | 137 A | |||
Inrush Current (3 seconds)(2) 150V | 410 A | 837 A | |||
Inrush Current (3 seconds)(2) 300V | 205 A | 410 A | |||
3PH | RMS continuous (2) 150V | 137 A | 279 A | ||
RMS continuous (2) 300V | 68 A | 137 A | |||
Inrush Current (3 seconds)(2) 150V | 410 A | 837 A | |||
Inrush Current (3 seconds)(2) 300V | 205 A | 410 A | |||
Countinous function (Max current) |
1PH | RMS continuous (2) 150V | 228 A | 465 A | |
RMS continuous (2) 300V | 114 A | 228 A | |||
3PH | RMS continuous (2) 150V | 228 A | 465 A | ||
RMS continuous (2) 300V | 114 A | 228 A | |||
FREQUENCY | Output frequency range | 50Hz(5) – 80Hz | 50Hz(5) – 80Hz | ||
Range of synchronization | 45Hz – 65Hz | 45Hz – 65Hz | |||
Frequency resolution | 0.02Hz | 0.02Hz | |||
Frequency precision | 100ppm | 100ppm | |||
SUPPLY | Input supply | 400Vac±10% 3PH | 400Vac±10% 3PH | ||
Maximum Input current | 250A | 500A | |||
Input Frequency | 47Hz-63Hz | 47Hz-63Hz | |||
OTHER | Size (H : W : D) | 1670 : 920 : 825 | 1800 :1200 : 1000 | ||
Weight | 800 kg | 1400 Kg | |||
Protections | OVP,UVP;OTP | OVP,UVP;OTP | |||
Operation Temperature Range | 0-35°C | 0-35°C | |||
RS232 | YES | YES | |||
RS485 | OPTION | OPTION | |||
LAN | OPTION | OPTION | |||
Firmware with SCPI | OPTION | OPTION | |||
Remote program | PS Interface | PS Interface | |||
Driver Labview | PS Driver rev. 1 | PS Driver rev. 1 | |||
Manual | 62000590_it_en 62000590_de_es Quick start guide Startup sequence |
62000590_it_en 62000590_de_es Quick start guide Startup sequence |
|||
Brochure | HPS 100KVA | HPS 200KVA | |||
FILTERS | Three phase | ● | ● | ||
Isolated | ● | ● | |||
Double range | ● | ● | |||
OVP = Over voltage protection
UVP = Under voltage protection OTP = Over temperature protectionf.s. = Full scale (2) With Resistive load (3) Desk and Rack version (5) It is possible on remote interface to set 10Hz but you must decrease the maximum voltage (6) It is possible to use in single phase mode but with 1/3 of nominal power. It is possible asymmetrical output current |